CVE-2025-69425

N/A Unknown
Published: January 09, 2026 Modified: January 13, 2026
View on NVD

Description

The Ruckus vRIoT IoT Controller firmware versions prior to 3.0.0.0 (GA) expose a command execution service on TCP port 2004 running with root privileges. Authentication to this service relies on a hardcoded Time-based One-Time Password (TOTP) secret and an embedded static token. An attacker who extracts these credentials from the appliance or a compromised device can generate valid authentication tokens and execute arbitrary OS commands with root privileges, resulting in complete system compromise.

AI Explanation

Get an AI-powered plain-language explanation of this vulnerability and remediation steps.

Login to generate AI explanation

References to Advisories, Solutions, and Tools

Patch Vendor Advisory Exploit Third Party Advisory

2 reference(s) from NVD

Quick Stats

CVSS v3 Score
N/A / 10.0
EPSS (Exploit Probability)
0.0%
14th percentile
Exploitation Status
Not in CISA KEV

Weaknesses (CWE)